Reset sequence for pinch protection
If any fault arises with the electrical functions of the power windows, a reset sequence can be tested.
The electrically-operated sun blinds* have a reset sequence that can be tested in the event of problems.
If the starter battery is disconnected, the automatic opening and closing function must be reset to work properly. A reset must take place for pinch protection to work.Warning
If the problem persists, or if it concerns the panoramic roof or sunroof, contact a workshop.[1]
Reset the power window
- Start with the window in closed position.
- Then operate it in the manual position 3 times upwards to closed position.The system is initiated automatically.
Reset sun blind
- Start with the sun blind* retracted.
- Press the control against retracting mode for approx. 15 seconds.The system is initialised automatically.